Sokkia SET 230-RS Total Station Operators Manual

Sokkia SET 30R Total Station Operations Manual and Guide


From extra long distances to remarkably short ones, the Sokkia series 30R offers accurate reflectorless measurement over a tremendous range of distances. The series 30R3 total stations feature a class 3R laser and cover a range from 1ft. to 1140ft. The series 30R total stations feature a class 2 laser and cover a range up to 490ft. With its narrow beam, distances to walls and corners can be measured with pin point accuracy. You can switch between reflectorless, prism and reflective sheet targets just by pressing the SFT key in sequence. The selected target is displayed on the screen for easy confirmation.

Specifications

β€’ 30 power telescope; minimum focusing distance 4.3 ft.

β€’ angle accuracy 5" 530R, 530R3 3" 330R, 330R3 2" 230R, 230R3

β€’ Dual axis compensator

β€’ Laser Output: 30R class 2, prism mode 30R class 1

β€’ Laser Output: 30R3 class3R, prism mode 30R3 class 1

β€’ Units: meters/feet/feet inches selectable β€’ Measurement range: 30R reflectorless up to 490ft, 30R to mini prism 1640ft, 30R to single prism 13,120ft

β€’ Measurement range: 30R3 reflectorless up to 1140ft, 30R3 to mini prism 2620ft, 30R3 to single prism 13,120ft

β€’ Measurement Accuracy: reflectorless fi ne mode30R 1ft to 320ft +/- (3+2ppm x d) mm 320ft to 490ft +/- (5+ 10 ppm x d) mm

β€’ Measurement Accuracy: reflectorless fi ne mode 30R3 1ft to 650ft +/- (3+2ppm x d) mm 650ft to 1140ft +/- (5 + 10 ppm x d) mm

β€’ Measure modes: Fine, rapid, tracking

β€’ Data Storage: 10,000 points β€’ Interface: RS232C compatible. Baud rate 1200 to 38,400 bps.

β€’ Display/Keyboard: Alphanumeric/graphic dot matrix LCD, 192 x 80 dots with backlight & contrast adjustment, 4 soft keys and 11 keys

β€’ Control panel location: both faces

β€’ Laser pointer function: on/off selectable

β€’ Plate vial sensitivity: 30" Set 330R3, Set 530R3, Set 330R, Set 530R & 20" vials on Set 230R3, Set 230R

β€’ Optical Plummet β€’ Weight with handle and battery: 12lbs.

β€’ Power Supply: 7.2v DC 2 batteries included

β€’ Battery Run Time: 30R3 Approximately 5.5 hours for single measurement every 30 seconds, approximately 8.5 hours for angle measurement only. 30R series approximately 6 hours for single measurement every 30 seconds. Approximately 8.5 hours for angle measurement only β€’ Recharging time: within 2 hours with standard quick chargers

β€’ Auto power cut-off: 30,15,10,5 minutes or none selectable